Conclusions
Using the high sensitivity AxION 2 TOF, we were able to detect 0.2 mg/Kg of BADGE in tuna extract well below the regulation limits set at 1 mg/Kg. Using the high mass accuracy capability of AxION 2 TOF along with the AxION EC ID software, we were able to detect unknown peaks and match them to the isomers BADGE.BPA linear structure/cyclo-di-BADGE structures without the use of authentic standards.
Dr. Reddy is an applications scientist for PerkinElmer Inc., Shelton, Conn. Reach her at [email protected]. Dr. Rakov is also works for PerkinElmer in the Branford, Conn. facility. Reach him at [email protected].
Acknowledgements: We thank Ariovaldo Bisi and Lucca Piatti, PerkinElmer, Italy for the BADGE standard and tuna samples.
REFERENCES
1. Cao XL, Dufresne G, Clement G, Bélisle S, Robichaud A, Beraldin F. JAOAC Int 92 (2009) 1780.
2. Míguez J, Herrero C, Quintás I, Rodríguez C, Gigosos PG, Mariz OC. Food Chem. 135 (2012) 1310.
3. Schug T, Janesick A, Blumberg B, Heindel J Steroid Biochem Mol Biol. 127 (2011) 204.
4. Schaefer A, Simat T.J. Food Additives &Contaminants, 21 (2004) 390.
Leave a Reply